§ 23.25.1207.3. Temporary gas installations—Permit not required.  


Latest version.
  • Amend section 1207 by adding a new section 1207.3 as follows:

    1207.3 Temporary gas installations—Permit not required. A permit and inspection shall not be required for residential temporary construction heat serving tented footings and foundations. This provision is for thawing ground and curing concrete, not comfort heat for workers, such as plumbers installing underground. This allowance is limited to portable "SURE FLAME" type heaters and not intended for unit heaters, furnaces, and boilers with special venting considerations. All heaters and hoses shall be of the approved type. Heaters shall be listed by an approved listing agency. All hoses shall have an internal wire mesh or braid, and be "kink proof". Supporting wire shall run the full length of the hose. One hundred percent (100%) outside air shall be provided to heater at all times. Listed clearances to combustibles shall be maintained. A licensed journeyman plumber or gasfitter shall perform all work.

( AO No. 2015-127, § 1, 4-1-16 )