§ 23.25.604.9. Materials - plastic pipe materials.  


Latest version.
  • Amend by deleting paragraph 604.9 and the exception and substitute the following:

    Plastic piping materials shall not be used for water service piping from the street service main, private well, or other water source to a building or premises.

    Exception: PVC or HDPE water service pipe 4 inch in diameter and greater may extend from the utility main horizontally into the footprint of the building. The piping shall transition underground to an approved metallic pipe at a 90 degree fitting. The PVC and HDPE pipe and fittings shall comply with the latest version of the Anchorage Water and Wastewater Utility (AWWU) Design Construction Practice Manual (DCPM).

( AO No. 2015-127, § 1, 4-1-16 )