§ 23.25.320.0. Mezzanines and platforms.  


Latest version.
  • Add new section as follows:

    Every mezzanine or platform containing appliances or equipment requiring access more than ten feet, six inches above the ground or floor level shall be made accessible by a stairway or ladder fastened to the structure. The ladder shall be constructed with:

    1.

    Rung spacing not to exceed fourteen (14) inches on center.

    2.

    Toe spacing not less than six (6) inches deep.

    3.

    At least 18" spacing between rails.

    4.

    Rungs at least 0.75 inches in diameter capable of withstanding a 300 lb. load.

    5.

    Offset sections and landings capable of withstanding 100 pounds per square foot when heights exceed 30 feet.

( AO No. 2015-127, § 1, 4-1-16 )