Anchorage |
Code of Ordinances |
Title 23. BUILDING CODES |
Chapter 23.20. LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION |
§ 23.20.100. Local amendments to the International Mechanical Code 2012 Edition. |
§ 23.20.101.2. Scope. |
§ 23.20.103—23.20.110. |
§ 23.20.202. General definitions. |
§ 23.20.302. Protection of structure. |
§ 23.20.303.4. Protection from damage. |
§ 23.20.304.3. Elevation of ignition source. |
§ 23.20.304.13. Aircraft hangars. |
§ 23.20.306.3. Appliances in attics. |
§ 23.20.306.4. Appliances under floors. |
§ 23.20.306.5. Equipment and appliances on roofs or elevated structures. |
§ 23.20.306.5.2. Electrical requirements. |
§ 23.20.306.6. Mezzanines and platforms. |
§ 23.20.401.2. Ventilation required. |
§ 23.20.401.4.1. Mechanical intake openings serving single-family dwelling units. |
§ 23.20. Table 401.5. Opening sizes in louvers, grilles and screens protecting air intake openings. |
§ 23.20. Table 403.3. Minimum ventilation rates. |
§ 23.20. Table 403.3.1.2. Zone air distribution effectiveness. |
§ 23.20.501.3. Exhaust discharge. |
§ 23.20.501.3.1.1. Exhaust discharge. |
§ 23.20.501.3.2. Exhaust opening protection. |
§ 23.20.504.6.4.2. Manufacturer's instructions. |
§ 23.20.504.6.5. Length identification. |
§ 23.20.505.1. Domestic systems. |
§ 23.20.505.2. Makeup air required. |
§ 23.20.507.2.1.1. Operation. |
§ 23.20.507.2.3. Domestic cooking appliances used for commercial purposes. |
§ 23.20.507.9. Clearances for Type I hood. |
§ 23.20.511.1. Dust, stock and refuse conveying systems. |
§ 23.20.515.1. Multi-port exhaust fans. |
§ 23.20.601.4. Contamination prevention. |
§ 23.20.602.1. General. |
§ 23.20.702. Circulation of air. |
§ 23.20.801.20. Plastic vent joints. |
§ 23.20.801.21. Location and support of venting systems other than masonry chimneys. |
§ 23.20.802.9. Vent terminals - ice and snow protection. |
§ 23.20.804.3.4. Horizontal terminations. |
§ 23.20.918.6. Prohibited sources. |
§ 23.20.923.2. Small ceramic kilns - ventilation. |
§ 23.20.928. Evaporative cooling equipment. |
§ 23.20.1001.1. Scope. |
§ 23.20.1004.4. Mounting. |
§ 23.20.1006.6. Safety and relief valve discharge. |
§ 23.20.1006.7. Boiler safety devices. |
§ 23.20. Table 1006.7. Controls and Limit Devices for Automatic Boilers. |
§ 23.20.1006.8. Electrical requirements. |
§ 23.20.1007. Boiler low-water cutoff. |
§ 23.20.1105.3. Refrigerant detector. |
§ 23.20.1105.6.2. Make-up air. |
§ 23.20.1105. Machinery room, general requirements. |
§ 23.20.1301.1. Scope. |