§ 23.100.070. Area and height limitations.  


Latest version.
  • Individual shelters shall not exceed two thousand five hundred (2,500) square feet of usable floor area. Where two or more shelters are grouped together (or "nested" in "T-Hangar" configuration), the total gross floor area of such grouping shall not exceed twenty thousand (20,000) square feet on non-combustible construction without an approved area separation wall.

    A.

    Adjacent shelters may be joined with non-combustible materials of similar design to original construction providing that they are separated by a one (1) hour rated fire door and applicable hardware. All floors shall be ground level, and no balcony or mezzanine floors shall be permitted, except that the areas which are not in the landing gear "footprint" may be insulated with insulfoam covered with plywood where said exposed materials are covered with an approved, rated, fire retardant coating.

    B.

    Minimum spacing between groupings of shelters shall be sixty-five (65) feet, except when an area separation wall is provided as noted above and in concert with applicable building and fire codes. Maximum height of any portion of the structure above grade shall be twenty-five (25) feet, and subject to the appropriate, approved and adopted airport height zoning map.

( AO No. 2015-127, § 1, 4-1-16 )